GuangDong Heng AnShun Electrical Power Equipment Service Co., Ltd.

Strive to establish leadership in China's electric power equipment industry.

Manufacturer from China
Active Member
2 Years
Home / Products / High Voltage Isolator Switch /

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Contact Now
GuangDong Heng AnShun Electrical Power Equipment Service Co., Ltd.
Country/Region:china
Contact Person:MissSherlin
Contact Now

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Ask Latest Price
Video Channel
Brand Name :HengAnshun
Model Number :GW9-10/1250A
Place of Origin :China
MOQ :3units(1group)
Price :USD241/Unit Based on EXW
Supply Ability :10000 units/month
Delivery Time :10 work days
Packaging Details :Export wooden case packing
Type :High voltage hookstick switch
Application :Outdoor
Keywords :Vertical Break Switch
Feature :Small Space
Max. Current :1250A
Material :Porcelain/stainless steel/steel
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Product Description:


The main purpose of high voltage isolator switch is to provide a means of safely disconnecting a section of a high voltage circuit for maintenance or repair work. When the switch is open, it creates an air gap between the two conductive parts of the circuit, effectively isolating the section from the rest of the system.
High voltage isolator switches are typically made of materials that are highly resistant to electrical arcing and corrosion, such as porcelain or polymer. They may also be designed with specialized features such as insulating barriers, arc chutes, and earth switches to improve their performance and safety.
It is important to note that high voltage isolator switches should only be operated by trained and qualified personnel, as they can pose a serious risk of electrical shock or injury if mishandled.

Application:


1.Circuit Isolation: High voltage isolator switches are used to isolate a section of a high voltage circuit for maintenance, repair, or testing purposes. By opening the switch, the section can be effectively disconnected from the rest of the system, allowing work to be carried out safely.
2.Load Switching: High voltage isolator switches can be used as load switches to control the flow of electrical power in a circuit. They are particularly useful in situations where the load is relatively small and does not require a circuit breaker or fuse.
3.Overhead Line Protection: High voltage isolator switches are often installed on overhead power lines to provide protection against lightning strikes and other electrical disturbances. By isolating a section of the line, the switch can help prevent damage to equipment and reduce the risk of power outages.
4.Transformer Protection: High voltage isolator switches are also used to protect transformers by isolating them from the electrical network in the event of a fault or overload. By opening the switch, the transformer can be disconnected from the network, preventing damage to the transformer and other equipment.

Operation:

1.Closing the Switch: When the switch is closed, the two conductive parts of the circuit are brought into contact with each other, allowing electrical current to flow through the circuit.
2.Opening the Switch: When the switch is opened, an air gap is created between the two conductive parts of the circuit, effectively isolating the section from the rest of the system. This is typically done to allow maintenance, repair, or testing work to be carried out safely.
3.Grounding the Circuit: Before any work can be carried out on the isolated section of the circuit, it is important to ground the circuit to prevent any residual electrical charge from building up. This is typically done using an earth switch or grounding electrode.

It is important to note that the operation of high voltage isolator switches should only be carried out by trained and qualified personnel, as they can pose a serious risk of electrical shock or injury if mishandled. In addition, it is important to follow all safety procedures and guidelines when working with high voltage equipment, including wearing appropriate protective clothing and equipment, using insulated tools, and ensuring that the area is clear of any flammable or explosive materials.

Feature:

1.High Voltage Rating: High voltage isolator switches are designed to withstand high levels of voltage, typically ranging from several thousand volts to several hundred thousand volts.
2.Robust Construction: High voltage isolator switches are typically made of materials that are highly resistant to electrical arcing, corrosion, and other forms of damage, such as porcelain or polymer.
3.Arc Chutes: Many high voltage isolator switches are designed with arc chutes, which help to dissipate the heat generated by electrical arcing and prevent damage to the switch.
4.Earth Switch: Some high voltage isolator switches are equipped with an earth switch, which provides an additional level of safety by grounding the isolated section of the circuit.
5.Interlocking Mechanism: To prevent accidental closure of the switch while maintenance work is being carried out, many high voltage isolator switches are equipped with an interlocking mechanism that prevents the switch from being closed until all safety procedures have been followed.
6.Visual Indicators: High voltage isolator switches may also include visual indicators, such as lights or flags, that provide a clear indication of whether the switch is in the open or closed position.

Technical Parameters:


Serial No. Parameter Unit Data
1 Rated Voltage kV 12
2 Rated Current Model No. (H)GW9-12(W)/630-20 A 630
(H)GW9-12(W)/1000-20 1000
(H)GW9-12(W)/1250-31.5 1250
3 4s Short-time withstanding current Model No. (H)GW9-12(W)/630-20 kA 50
(H)GW9-12(W)/1000-20 50
(H)GW9-12(W)/1250-31.5 80
4 Rated Insulation Level Lightning surge withstand voltage(peak) Polar-to-Earth
(Positive & Negative)
kV 75
Interfracture
(Positive & Negative)
85
Industrial frequency withstand voltage
(1 min)
(Effective value)
Dry Test/Wet Test Polar-to-Earth 42(Dry)
34(Wet)
Interfracture 48(Dry)
48(Dry)
48(Dry)
40(Wet)
5 Main Circuit Resistance μ Ω 630
1000
1250
6 Mechanical Life Time times 50
50
80

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break SwitchPorcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Porcelain High Voltage Isolator Switch Easy Installation 1250A For Circuit Breaker Vertical Break Switch

Inquiry Cart 0